The Canalta Dual Chamber Orifice Fitting allows for accurate flow measurements, orifice plate inspection and changing without breaking apart or depressurizing the flow line.
Parts matter, whatever your service environment.
Our standard zinc-plated 4130 carbon steel internals offer superior corrosion
protection and resistance to sulfide or hydrogen induced cracking, providing
reliability and performance over a long service life. These parts conform to
NACE MR0175 / ISO 15156:2003 specifications.
For extreme corrosive applications, such as wet H2S service, 316 stainless steel
internals are available to protect against general and localized corrosion.
Canalta has endeavoured to ensure that our parts and accessories offerings
are interchangeable with the current industry standard orifice fitting brand,
making Canalta Orifice Fitting internals suitable for re-builds and re-works of
our competitors’ product lines.
HNBR O-ring Seals on both the body and seal bar come standard with all Canalta Dual Chamber Orifice Fittings. This feature eliminates
nuisance gasket maintenance and clamping bar screw breakage, while providing superior sealing capability. The O-rings incorporated are
standard shelf sizes and can be supplied in a wide variety of compositions. Gaskets are also available and can be used when preferred or required.
The Soft Seat Valve Seal is available for all dual chamber models. Particularly suited to low pressure applications,
this unique design enables a bubble-tight seal between the upper and lower chambers without the need for frequent lubrication.
The specially machined seal channel helps prevent O-ring dislocation, and the O-ring seals incorporated are available in a wide
variety of compositions.
| Design | ................................... |
|
| Internal Parts | ................................... | AISI 4130 Carbon Steel, 316 or A351 CF8M Stainless Steel |
| Sizes and ANSI Class | ................................... |
|
| U/S D/S Connections | ................................... |
|
| Internal Bore Size | ................................... | 40, 60, 80, 100, 120, 160 and custom sizes |
| Sealing Compounds | ................................... |
|
| Line Bore I.D. Tolerance | ................................... | In conformance with AGA-3 and ISO-5167 Latest Edition |
| Eccentricity Repeatability | ................................... | In conformance with AGA-3 and ISO-5167 Latest Edition |
| Tap Connections | ................................... |
|
| Orifice Plate Seal Gap | ................................... |
|
| Operating Shaft Location | ................................... |
|
| Operating Temperature | ................................... | Standard at -20° to 100° F, optional -40° to 1200° F |
| Operating Position | ................................... | Vertical or horizontal |
An AGA 2000 Inspection report is included with the purchase of every fitting. The documented test include:
|
|
|